【科研】顱內(nèi)動(dòng)脈管壁成像技術(shù)到底走了多遠(yuǎn)?


1.顱內(nèi)動(dòng)脈特點(diǎn)

圖片

  • 血管特別細(xì),管壁薄。以大腦中動(dòng)脈為例,直徑范圍在3-5mm,管壁厚度在0.5-0.7mm.大腦中動(dòng)脈往下還有更細(xì)的分支。

  • 顱內(nèi)血管多迂曲盤繞,并不是像頸動(dòng)脈那樣,如一條直線延展。


2.顱內(nèi)動(dòng)脈管壁圖像采集技術(shù)

  • 目前比較一致的共識(shí)是:最好是使用3T場(chǎng)強(qiáng)的磁共振設(shè)備,序列偏向于3D黑血序列。

  • 常見主流廠家的3D序列主要有:SPACE, CUBE, VISTA,有學(xué)者對(duì)采集技術(shù)做了優(yōu)化,節(jié)省掃描時(shí)間,提高圖像質(zhì)量(圖像覆蓋范圍更廣,且能更好地抑制腦脊液信號(hào))      

  • 當(dāng)然之前也有很多學(xué)者用2D序列(T1,T2,PDW)研究顱內(nèi)動(dòng)脈管壁,做出了成果。 

                                                                       

3.顱內(nèi)動(dòng)脈管壁圖像后處理技術(shù)

  • 目前,后處理技術(shù)可以實(shí)現(xiàn)對(duì)管壁負(fù)荷的分析:管壁管腔面積,體積,最大管壁厚度,標(biāo)準(zhǔn)化管壁指數(shù)等

  • 如大家所知,MRI-PlaqueView 是一款經(jīng)典的血管斑塊分析軟件,對(duì)顱外頸動(dòng)脈段的斑塊分析在臨床上有明確應(yīng)用價(jià)值,已經(jīng)獲得FDA/CFDA的臨床應(yīng)用許可。如需要針對(duì)顱內(nèi)血管斑塊進(jìn)行分析和評(píng)估,一個(gè)簡(jiǎn)單的方式就是,利用一個(gè)前置的插件系統(tǒng):MRI-PlaqueView (3D-Pre),將原始數(shù)據(jù)進(jìn)行預(yù)處理后輸出給MRI-PlaqueView,就可以實(shí)現(xiàn)對(duì)顱內(nèi)血管的斑塊負(fù)荷及成分的定量分析,這個(gè)方法對(duì)于臨床研究有很強(qiáng)的實(shí)用性及便捷性。


4.顱內(nèi)動(dòng)脈管壁成像的臨床意義

  • 顱內(nèi)動(dòng)脈斑塊也是引起缺血性腦卒中的主要原因。

  • 前臨床常用的影像學(xué)檢查手段如MRA,CTA,DSA等,都只能看到斑塊造成的管腔狹窄率。

  • 動(dòng)脈炎,動(dòng)脈粥樣硬化等都可以造成管腔狹窄,但是病理機(jī)制以及治療方法截然不同,因此單看狹窄并不能滿足臨床診斷的需求。

  • 管壁成像技術(shù)可以幫助鑒別不同類型的血管疾病,確診有癥狀但不狹窄的顱內(nèi)動(dòng)脈疾病,確定斑塊位置、斑塊穩(wěn)定性,預(yù)測(cè)斑塊風(fēng)險(xiǎn)等。


參考文獻(xiàn):

1. Alexander MD, Yuan C, Rutman A, Tirschwell DL, Palagallo G, Gandhi D, Sekhar LN, Mossa-Basha M. High-resolution intracranial vessel wall imaging: imaging beyond the lumen. J Neurol Neurosurg Psychiatry. 2016;87(6):589–97. 2. Chung GH, Kwak HS, Hwang SB, Jin GY. High resolution MR imaging in patients with symptomatic middle cerebral artery stenosis. Eur J Radiol. 2012;81(12):4069–74. 

3.Fan Z, Yang Q, Deng Z, Li Y, Bi X, Song S, Li D. Whole-brain intracranial vessel wall imaging at 3 tesla using cerebrospinal fluid-attenuated T1weighted 3D turbo spin echo. Magn Reson Med. 2017;77(3):1142–50. 4. Yang H, Zhang X, Qin Q, Liu L, Wasserman BA, Qiao Y. Improved cerebrospinal fluid suppression for intracranial vessel wall MRI. J Magn Reson Imaging. 2016; 44(3):665–72. 

5. Yang Q, Deng Z, Bi X, Song SS, Schlick KH, Gonzalez NR, Li D, Fan Z. Wholebrain vessel wall MRI: a parameter tune-up solution to improve the scan efficiency of three-dimensional variable flip-angle turbo spin-echo. J Magn Reson Imaging. 2017;46(3):751–7. 

6.Mandell DM, Mossa-Basha M, Qiao Y, Hess CP, Hui F, Matouk C, Johnson MH, Daemen MJ, Vossough A, Edjlali M, et al. Intracranial Vessel Wall MRI: principles and expert consensus recommendations of the American Society of Neuroradiology. AJNR Am J Neuroradiol. 2017;38(2):218–29. 

7. Mihai G, Varghese J, Lu B, Zhu H, Simonetti OP, Rajagopalan S. Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI. J magn reson Imaging. 2015;41(1):202–12. 

8. Eikendal AL, Blomberg BA, Haaring C, Saam T, van der Geest RJ, Visser F, Bots ML, den Ruijter HM, Hoefer IE, Leiner T. 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study. J cardiovasc Magn Reson. 2016;18:20.


<  上一篇 下一篇  >

分享此文章